Technical Data
Technical data acoustic radiators
Acoustic radiators 180° formation
Sound level
|
113,0 dB(C) Leq Average in 30m
|
Sound radiation
|
360°
|
Basic frequency
|
415Hz/425Hz
|
Number of horns
|
8
|
Intermediate flange
|
8
|
Siren driver
|
8
|
Cover plate
|
1
|
Antenna flange
|
optional
|
Screw set
|
V2A
|
Connector plug
|
8
|
Total weight
|
94kg
|
Total height
|
2850mm
|
Width
|
820 x 160mm
|
Acoustic radiators 90° formation
Sound level
|
111,5 dB(C) Leq Average in 30m
|
Sound radiation
|
360°
|
Basic frequency
|
415Hz/425Hz
|
Number of horns
|
8
|
Intermediate flange
|
1
|
Siren driver
|
8
|
Cover plate
|
1
|
Antenna flange
|
optional
|
Screw set
|
V2A
|
Connector plug
|
8
|
Total weight
|
75kg
|
Total height
|
1620mm
|
Width
|
820
x 820mm
|
Electronic
Number of power amplifiers
|
4
|
Output power
|
1000W (reducible via software download in steps)
|
Number of different signals
|
2, optional up to 7
1 external clock input
|
Battery voltage / capacity
|
24V / 55Ah
|
Mains voltage
|
230V AC
|
Power consumption at rest with charged batteries
|
6VA
|
Number of alarms in event of power failure
|
at least 20 siren alarms of 1 min. duration over a period of 10 days at above 0°C
|
Temperature range electronics
|
-40°C to +70°C
|
Temperature range battery
|
-25°C to +60°C
|
Weight
|
87kg
|
Cabinet dimensions
|
600 x 1000 x 250mm (W x H x T)
|
Options
OPT-Siren 040
|
Local microphone (handheld microphone with preamplifier)
|
OPT-Siren 060
|
Solar operation
|
OPT-Siren 070
|
Antenna surge voltage conductor
|
OPT-Siren 080
|
Antenna carrier
|
OPT-Siren 090
|
Holder for remote control receiver
|
OPT-Siren 100
|
100V-ELA technique
|
OPT-Siren 120
|
Programming adapter
|
|