DK Safety Warning Systems |
|
Siren 250-2000 M10 |
|
Siren 2000 M10 |
|
|
|
|
|
(1) The Siren 2000 M10 electronic siren serves to alert the fire and rescue services and to warn the public in the event of an emergency.
(2) The system consists of an electronic control unit and two acoustic radiators. The current required for operation is taken from two absolutely maintenance-free lead batteries. Prolonged operation is guaranteed even in the event of a power failure. Mains-independent operation on a solar power supply is also possible as an option.
(3) The control unit contains 8 short-circuit-proof, overtemperature-protected low frequency amplifiers with two 125W output power each.
(4) The processor module UP98 takes over optional controls. This also accommodates the radio interface and the digital voice memory module providing these options have been ordered.
(5) The SLG98 power supply unit provides a temperature-compensated and conserving charging of the batteries. It also supplies the voltages required for the system. For feeding of a two way-radio a 12 volts / 0.4 A power supply is already built in. If necessary, a converter module at 50W can be optionally adapted for feeding a radio system. This reduces the 24 V battery voltage to the 12 V supply voltage without losses. This unit also contains the charge controller for alternative solar energy supply.
(6) The individual components are linked by the connection card VPE98. The optocoupler inputs also on this guarantee electrical isolation from external devices
(7) A notebook or a service device can be connected via a programming adapter to a 37-pin SUB-D socket. This can be used to check the operating states of the system and load new program routines.
(8) The various terminals, fuse holders and an overvoltage protection element for the 230 V mains supply voltage are located on the mounting rail. An optional overvoltage protection can be installed in the antenna cable.
(9) The complete electronics, including the batteries are installed in a steel cabinet with the dimensions 600x1000x350mm. The cabinet is electrophoretically dipped and powder coated with RAL 7032.
(10) The cable inlets for mains and external alarm generators and the acoustic radiators are on the bottom of the machine.
(11) The basic equipment includes a connection possibility for an external radio control as well as a fire and fire drill alarm.
(12) A radio control, an operating and display panel, a handheld microphone with preamplifier and a digital voice memory with 180 s recording time can be integrated as options in the cabinet. The operating and display panel can also be fitted with a goose-neck microphone and is available in remote form as a desktop or wall-mounted model.
(13) The outdoor unit consists of sixteen acoustic radiators with the appropriate flanges and covers. They are made of corrosion-resistant diecast aluminum. All screws and fastenings are made of stainless steel. An antenna carrier can be mounted optionally.
(14) The use of high-quality, reliable components mean that no maintenance work is necessary in the whole system. The required technical data are fully complied with in a temperature range from -40° to +70° Celsius. However, the use of lead batteries restricts the application to-25° Celsius. In this range the capacity may drop dependent to the load. |
|
|
|
|
|
|
|
|
Technical data
Soundlevel in dB(A) SPL at a distance of 30m
|
Omnidirectional 180°(Average)
|
121
|
Omnidirectional 360°(Average)
|
119.5
|
Directed 0°(Peak)
|
---
|
Directed 20°(Peak)
|
125
|
Basic frequency
|
410/425Hz
|
Temperature range
|
-50°C to +70°C
|
Number of Horns
|
16
|
Total weight in kg:
|
Omnidirectional 180°
|
188
|
Omnidirectional 360°
|
150
|
Directed 0°
|
---
|
Directed 20°
|
184
|
Cubic unit(w x h x d) in mm
|
Omnidirectional 180°
|
830 x 5430 x 160
|
Omnidirectional 360°
|
830 x 3200 x 830
|
Directed 0°
|
---
|
Directed 20°
|
630 x 5430 x 720
|
AV = Average Leq in 30m about 360°
Peak = Leq in 30m - preferential direction
Leq = equivalent steady sound level acc to DIN IEC 804
Electronic
Power output RMS
|
2000W via service unit reduceable in 3 dB steps
|
potential-free input for siren signals
|
2/7
|
potential-free clock input
|
1
|
Power supply
|
230V AC
|
Power input in stand-by mode
|
6VA
|
current consumption during power failure in standby mode
|
65mA/120mA/M05
|
Number of alarms during power failure
|
at least 20 siren alarms of 1 min. duration over a period of 10 days at above 0°C
|
Temperature range for electronics
|
-40°C to +70°C
|
Temperature range for battery
|
-25°C to +60°C
|
Cubic unit (w x h x d in mm)
|
600 x 1000 x 350mm
|
degree of protection
|
IP 54
|
Weight in kg
|
170
|
Battery
|
2x12V
|
Nominal capacity C20
|
115Ah
|
Options
OPT-Siren 010
|
Radio interface
|
OPT-Siren 020
|
Operating and display panel “internal”
|
OPT-Siren 030
|
Operating and display panel “external”
|
OPT-Siren 040
|
Local microphone (handheld microphone with preamplifier and tape recorder input)
|
OPT-Siren 050
|
Digital voice memory 180sec.
|
OPT-Siren 060
|
Solar operation
|
OPT-Siren 070
|
Antenna surge voltage conductor
|
OPT-Siren 080
|
Antenna carrier
|
OPT-Siren 090
|
Holder and wiring for radio control
|
OPT-Siren 100
|
100V ELA-technique
|
OPT-Siren 110
|
Converter module 24/12V - 4A
|
OPT-Siren 120
|
Programming adapter
|
OPT-Siren 130
|
Common trouble indentification via potentialfree relay-contact as an option.
|
|
|
|
|
|
|
|
|
|
|